HomeM8×0.75 › M8×0.75 torque spec

M8×0.75 Torque Spec

Calculated preload torque by grade, plus what actually changes the number.

M8×0.75 · 8.8 · dry threads 29.1 N·m 21.5 lb-ft · targets 18.2 kN clamp load (75% of proof)

By grade

GradeDry (N·m)Lubed (N·m)Dry (lb-ft)Clamp loadUltimate tensile
4.6
Low-carbon steel, general purpose
11.38.478.337.1 kN16.7 kN
8.8
Medium-carbon, quenched & tempered — the default structural grade
29.121.821.518.2 kN33.4 kN
10.9
Alloy steel, Q&T — high strength
41.631.230.726 kN43.5 kN
12.9
Alloy steel, Q&T — highest common grade (socket head cap screws)
48.736.535.930.4 kN51 kN
A2-70
304 stainless, cold worked
22.616.916.714.1 kN29.3 kN

Why lubrication changes everything

Roughly 90% of the torque you apply is consumed by friction — under the head and in the threads. Only about 10% becomes useful bolt stretch. That means the friction coefficient, not the bolt, sets the relationship between torque and clamp load. Here is the same M8×0.75 8.8 fastener under different conditions:

Thread conditionNut factor KTorque for same preload
Plain / as-received, dry0.2029.1 N·m
Zinc plated, dry0.2232 N·m
Black oxide, lightly oiled0.1826.2 N·m
Machine oil on threads0.1521.8 N·m
Molybdenum disulfide / anti-seize0.1217.5 N·m
Waxed or PTFE coated0.1014.6 N·m
Torquing a lubricated bolt to the dry spec overloads it — the 14.6 N·m row and the 29.1 N·m row produce the same clamp load. Apply the dry number to a waxed fastener and you are at roughly twice the intended preload, which for a 8.8 is past yield.

Assumptions behind these numbers

T = K × D × F with K = 0.20, F = 0.75 × proof load, and proof load = tensile stress area (41.81 mm²) × the grade's proof strength. This is a general-engineering starting point for a reusable steel-on-steel joint. It is not a substitute for a manufacturer's torque sequence on an engine, a suspension component, a pressure vessel or any structural connection.