Home9/16-18 UNF › 9/16-18 UNF torque spec

9/16-18 UNF Torque Spec

Calculated preload torque by grade, plus what actually changes the number.

9/16-18 UNF · Grade 5 · dry threads 121 lb-ft 164 N·m · targets 12940 lb clamp load (75% of proof)

By grade

GradeDry (lb-ft)Lubed (lb-ft)Dry (N·m)Clamp loadUltimate tensile
Grade 2
Low/medium carbon steel, unmarked head
78.558.91068,372 lb15,020 lb
Grade 5
Medium carbon Q&T, 3 radial head marks
1219116412,940 lb24,357 lb
Grade 8
Medium carbon alloy Q&T, 6 radial head marks
17112823218,268 lb30,447 lb
18-8 SS
304/18-8 stainless
57.142.877.46,089 lb15,223 lb

Why lubrication changes everything

Roughly 90% of the torque you apply is consumed by friction — under the head and in the threads. Only about 10% becomes useful bolt stretch. That means the friction coefficient, not the bolt, sets the relationship between torque and clamp load. Here is the same 9/16-18 UNF Grade 5 fastener under different conditions:

Thread conditionNut factor KTorque for same preload
Plain / as-received, dry0.20121 lb-ft
Zinc plated, dry0.22133 lb-ft
Black oxide, lightly oiled0.18109 lb-ft
Machine oil on threads0.1591 lb-ft
Molybdenum disulfide / anti-seize0.1272.8 lb-ft
Waxed or PTFE coated0.1060.7 lb-ft
Torquing a lubricated bolt to the dry spec overloads it — the 60.7 lb-ft row and the 121 lb-ft row produce the same clamp load. Apply the dry number to a waxed fastener and you are at roughly twice the intended preload, which for a Grade 5 is past yield.

Assumptions behind these numbers

T = K × D × F with K = 0.20, F = 0.75 × proof load, and proof load = tensile stress area (0.20298 in²) × the grade's proof strength. This is a general-engineering starting point for a reusable steel-on-steel joint. It is not a substitute for a manufacturer's torque sequence on an engine, a suspension component, a pressure vessel or any structural connection.

Related for 9/16-18 UNF