Home#12-24 UNC › #12-24 UNC torque spec

#12-24 UNC Torque Spec

Calculated preload torque by grade, plus what actually changes the number.

#12-24 UNC · Grade 5 · dry threads 5.55 lb-ft 7.52 N·m · targets 1540 lb clamp load (75% of proof)

By grade

GradeDry (lb-ft)Lubed (lb-ft)Dry (N·m)Clamp loadUltimate tensile
Grade 2
Low/medium carbon steel, unmarked head
3.592.694.87996 lb1,788 lb
Grade 5
Medium carbon Q&T, 3 radial head marks
5.554.167.521,540 lb2,899 lb
Grade 8
Medium carbon alloy Q&T, 6 radial head marks
7.835.8710.62,174 lb3,624 lb
18-8 SS
304/18-8 stainless
2.611.963.54724 lb1,812 lb

Why lubrication changes everything

Roughly 90% of the torque you apply is consumed by friction — under the head and in the threads. Only about 10% becomes useful bolt stretch. That means the friction coefficient, not the bolt, sets the relationship between torque and clamp load. Here is the same #12-24 UNC Grade 5 fastener under different conditions:

Thread conditionNut factor KTorque for same preload
Plain / as-received, dry0.205.55 lb-ft
Zinc plated, dry0.226.1 lb-ft
Black oxide, lightly oiled0.184.99 lb-ft
Machine oil on threads0.154.16 lb-ft
Molybdenum disulfide / anti-seize0.123.33 lb-ft
Waxed or PTFE coated0.102.77 lb-ft
Torquing a lubricated bolt to the dry spec overloads it — the 2.77 lb-ft row and the 5.55 lb-ft row produce the same clamp load. Apply the dry number to a waxed fastener and you are at roughly twice the intended preload, which for a Grade 5 is past yield.

Assumptions behind these numbers

T = K × D × F with K = 0.20, F = 0.75 × proof load, and proof load = tensile stress area (0.02416 in²) × the grade's proof strength. This is a general-engineering starting point for a reusable steel-on-steel joint. It is not a substitute for a manufacturer's torque sequence on an engine, a suspension component, a pressure vessel or any structural connection.

Related for #12-24 UNC